| Produktbezeichnung: |
Tempcore
(Maximilianshütte) |
[zurück
zur Übersicht] |
| Hersteller: |
|
Maximilianshütte GmbH (D) |
|
|
|
| Laufnummer: |
070 |
|
|
|
|
|
|
| SIA-Registerposition: |
18.1 |
|
|
|
|
|
|
| Registereintrag: |
1984 bis 1988 |
|
|
|
|
|
| Stahltyp: |
|
T |
|
|
|
|
|
|
| Durchmesser: |
8 bis 28 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Gewählte
Normengeneration |
SIA 162:1968 |
|
|
|
|
|
| Gewählter
Durchmesser: |
10 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Merkmal |
|
fy |
ft |
ψ |
λ10 |
λ5 |
λGL |
| |
|
|
[MPa] |
[MPa] |
[%] |
[%] |
[%] |
[%] |
| |
Probenumfang |
n [–] |
15 |
15 |
15 |
15 |
15 |
15 |
| Stichprobe |
Maximalwert |
MAX |
644 |
703 |
63 |
18 |
26 |
10.8 |
| Mittelwert |
AVG |
592 |
663 |
56.4 |
16.5 |
24 |
8.48 |
| Minimalwert |
MIN |
540 |
605 |
44 |
15.2 |
22 |
6.8 |
| Standardabweichung |
STD |
35.5 |
33.7 |
6.43 |
0.958 |
1.18 |
1.17 |
|
|
|
|
|
|
|
|
|